Power Automation Sweden AB

Cylindervägen 8
13152 Nacka Strand
Sweden
LG 5925/920

Safety Module for Safety Switches

LG 5925/920

Contacts

Nominal voltage

Terminal type

Approval

Variant

  • 0063683
  • LG5925.48/920/61 DC24V
Protection of people and machines Monitoring of safety gates Usage in furnace application... more

Product description

  • Protection of people and machines
  • Monitoring of safety gates
  • Usage in furnace application in continuous operation acc. to EN 50156-1

Technical specifications

Width: 22,5 mm
Cat. / PL acc. to EN ISO 13849-1: 4/e
SIL CL acc. to IEC/EN 62061: 3
Nominal voltage: DC
Thermal current Ith max.: 8 A
1- / 2-channel: 1, 2
Cross fault detection: Yes
Approvals: UL
Connection: S/PS/PC
Output contacts max.: 4 Schließer
Type: LG 5925/920

Features

  • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • According to EN 50156-2 for furnaces
  • To connect:
    - Safety switch NE 5020
    - Safety switch NE 5021
  • Output: max. 4 NO contacts, see contacts
  • 1- or 2-channel operation
  • Line fault detection on On-button
  • Manual restart or automatic restart, switch S2
  • with or without cross fault monitoring switch S1
  • LED indicator for state of operation
  • LED indicator for channel 1 and 2
  • Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
    2 x 2.5 mm2 solid DIN 46228-1/-2/-3/-4
  • As option with plugable terminal blocks for easy exchange of devices
    - With screw terminals
    - Or with cage clamp terminals
  • Width 22.5 mm